Accessories:
Mobile model, interior lightning, base frame, intake device and much more
Ambient temperature:
-20 - 43 °C
Bottle filling time:
1 min - 999 h 59 min
Certifications:
CE, Sampling according to ISO 5667-2/3-10
Communication:
Optional: PC via Software
Further communication options on request.
Controller:
Microprocessor control, Sleep-Mode (<5 mA), power supply 8-16 V, foil keyboard (with keys 0 - 9, ESC, ENT, cursor), graphical display (128 x 64 Pixel), backlit
Cooling principle:
Active cooling
Cooling system:
Self-contained, controlled cooling / heating with 4 settings, no-frost. independent of the programmable controller, temperature in sample compartment: 4 °C (adjustable from 0.0 - 9.9 °C)
Data storage:
3000 entries, non-volatile data memory; storage of sampling and malfunction data like sample extractions, bottle changes, messages, external signals
Dimensions:
* with opened top
1100 (1640*) mm x 760 mm x 745 mm (H x W x D)
Dosing system (sample):
Standard vacuum system
Sample volume selectable: 20 to 350 mL
Housing details:
- Double-walled PE plastic with 50 mm insulation
- Roof and cover material: Styrosun (GFK)
- Cover lifted by gas-shock absorbers, wind safe
- Easy to maintain
- Suction inlet from right-hand side of housing
Housing insulation material:
PUR
Housing material:
Made of PE with 50 mm insulation/Styrosun/PC (GF10) housing; separated in lower part (sample compartment) and upper part (controller and dosing system). Each part with lockable door resp. roof. Protective hood (made of Styrosun) which can be opened for operation of the control unit and service at the dosing unit.
PE
Housing type:
Stationary
Inputs:
1 x analogue: 0/4-20 mA
2 x digital (flow, event), Impulse length 60 ms, switching level 7-24 V, max. working resistance 500 Ohm, max. length of signal cable 30 m
Interface:
Mini-USB
Languages user interface:
Multi-language, selectable
Manual sampling:
Possible at any time, without interfering with the programme seqence.
Number of user programs:
6 user-defined sampling programs (freely programmable)
Operatin conditions:
Pressureless
Overfilling protection:
Adjustable from 1 - 999 samples/bottle
Pause Mode:
Interruption of program run at any time
Power requirements (Voltage):
115/230 V AC
Power supply:
Approx. 350 VA (with cooling)
Program protection:
Up to 5 years after voltage loss
Programs:
12 freely programmable user programs, with function to link programs
Program Start Options:
Immediately; at a certain time; by an external signal
Program Stop Options:
End of sampling program after one program run; continuous operation or x- runs, and a certain date / time
Sample container:
Plastic: 1 x 25 L; 1 x 50 L; 2 x 10 L; 4 x 10 L; 4 x 14 L; 12 x 2.9 L; 24 x 1.0 L
Glass: 12 x 2.0 L; 24 x 0.9 L
Sample interval:
1 min to 99 h 59 min in steps of 1 minute
1 to 9999 pulses/sample
Sampler type:
Stationary
Sample temperature:
0 - 40°C (32 - 104°F)
Sample transport velocity:
>0.5 m/s at suction height up to at least 8 m (at 1013 hPa); pump performance can be adjusted electronically
Sample volume:
20 - 350 mL freely adjustable
Sample volume accuracy:
1.5 % (95 % confidence interval)
Sampling mode:
Time-related, flow-proportional, constant time/ variable volume (CTVV), event-related, manual sample extraction
Sampling Principle:
Standard Vacuum System 20 - 350 mL
Option: glass dosing vessel instead of plastic
Status messages:
Standard: collective malfunction error message
Optional: Sampling, programme active, programme end message
Suction Height:
Max. 7.5 m (at 1013 hPa and stagnant medium), optional higher
Suction hose inner diameter (mm):
10 mm
Suction Hose Length:
7.5 m; max. hose length 30 m
Suction Hose Material:
PVC
Suction Hose Outer Diameter:
13 mm
Type of distributor:
Robust round distributor
Warranty:
24 months
Weight:
Approx. 75 kg with composite container, higher weight when using multi bottle option and/or glass bottles
Wetted Materials:
PC, PVC, Silicone, PS, PE, EPDM (optional: metering vessel glass Duran50, sinker weight SS304)