Alarm:
1 x malfunctioning, 4 x user-configurable, max. 24 VDC/0.5 A, potential free contacts
Ambient temperature:
10 - 30 °C ± 4 °C deviation at 5 - 95% relative humidity (non-condensing)
Analogue outputs:
Active 4 - 20 mA max. 500 Ohm load, standard 1, max. 8 (option)
Calibration:
N.A.
Certifications:
CE compliant / UL certified
Cycle Time:
20 - 30 minutes
40 minutes (+ Total Hardness Ca)
Demineralised water:
For rinsing
Detection limit:
≤ 10 mg/L
Digital outputs:
Optional: Modbus (TCP/IP, RS485)
Dimensions (H x W x D):
690 mm x 465 mm x 330 mm
Drain:
Atmospheric pressure, vented, min. Ø 32 mm
Earth connection:
Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm²
Flow rate:
100 - 300 mL/min
Instrument air:
Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air
Interferences:
Hardness: Some metal ions interfere by causing fading or indistinct end points or by stoichiometric consumption of EDTA. Suspended or colloidal organic matter also may interfere with the end point. Large amounts of colour and turbidity interferes. Fats, oil, proteins, surfactants and tar.
Alkalinity: Soaps, oily matter, suspended solids or precipitates may coat the glass electrode and cause a sluggish response. Allow additional time between titrant additions to let the electrode come to equilibrium or clean the electrodes occasionally.
Material:
Hinged part: Thermoform ABS, door: PMMA
Wall section: Galvanised steel, powder coated
Measurement method:
Acid-base titration (alkalinity only); Calmagite EDTA titration with LED dipping probe (combined)
Measuring range:
TH: 25 - 1000 mg/L CaCO₃; Alk: 100 - 5000 mg/L CaCO₃
Total Hardness: 25 - 1000 mg/L CaCO3
Alkalinity: 100 - 5000 mg/L CaCO3
Optional:
Total Hardness: 10 - 100 mg/L CaCO3
Alkalinity: 10 - 500 mg/L CaCO3
Total Hardness: 10 - 250 mg/L CaCO3
Alkalinity: 25 - 1250 mg/L CaCO3
Total Hardness: 25 - 500 mg/L CaCO3
Alkalinity: 50 - 2500 mg/L CaCO3
Method:
Titrimetric
Number of sample streams:
1, 2, 4 or 8
Parameter:
Hardness, total; Akalinity, total; Alkalinity, free
Power:
100 - 240 VAC, 50/60 Hz
Max. power consumption: 120 VA
Precision:
Better than 2% full scale range for standard test solutions
Protection class:
Protection class: Analyser cabinet: IP44 / Panel PC: IP65
Reagent Requirements:
Keep between 10 - 30 °C
Sample pressure:
By external overflow vessel
Sample quality:
Maximum particle size 100 µm, < 0.1 g/L; Turbidity < 50 NTU
Sample temperature:
10 - 30 °C
Validation:
Automatic; frequency freely programmable
Warranty:
24 months
Weight:
25 kg
What's included?:
EZ5005 Total Hardness and Free/Total Alkalinity Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets, 1 x pH Electrode, Routine S7 Connection, 1 x Photometer Probe, 3 x empty 2.5L Reagent Containers with Fittings (Buffer, Acid & Colour Solution) and 2 x empty 10L Reagents Containers with Fittings (EDTA & HCl Solution)