Ambient temperature:
                                            
                                            
                                        
									    5 - 45 °C
                                    
                                
    						
								
                                    
                                        
                                            
                                                Communication: digital:
                                            
                                            
                                        
									    Modbus RTU, Modbus TCP/IP & Profibus (when the Profibus option is selected, the digital output signals are sent through the Profibus converter with its specific communication protocol)
Except for Zone 1 certification then Modbus RTU, Modbus TCP/IP & Modbus TCP/IP Redundant is available
                                    
                                
    						
								
                                    
                                        
                                            
                                                Cycle Time:
                                            
                                            
                                        
									    From 5.5 minutes, depending on range and application
                                    
                                
    						
								
                                    
                                        
                                            
                                                Data storage:
                                            
                                            
                                        
									    Previous 9999 reaction data
                                    
                                
    						
								
                                    
                                        
                                            
                                                Display:
                                            
                                            
                                        
									    High contrast 40 character x 16 line backlit LCD with LED backlight
                                    
                                
    						
								
                                    
                                        
                                            
                                                EExp / Hazardous Location:
                                            
                                            
                                        
									    Certification options are available to European Standards, (ATEX Zone 1, Zone 2), North American Standards (Class I Division 2) and IECEx Zone 1
                                    
                                
    						
								
                                    
                                        
                                            
                                                Humidity:
                                            
                                            
                                        
									    5 - 85 % (non-condensing)
                                    
                                
    						
								
                                    
                                        
                                            
                                                Languages user interface:
                                            
                                            
                                        
									    English, Spanish, French, German
Others available upon request.
                                    
                                
    						
								
                                    
                                        
                                            
                                                Measurement method:
                                            
                                            
                                        
									    Infrared Measurement of CO₂ after Oxidation (DIN EN 1484:1997-08, ISO 8245:1999-03, EPA 415.1)
                                    
                                
    						
								
                                    
                                        
                                            
                                                Measuring range:
                                            
                                            
                                        
									    0 - 25 mg/L C
                                    
                                
    						
								
                                    
                                        
                                            
                                                Multi-Stream:
                                            
                                            
                                        
									    Up to 2 process streams and grab sample
                                    
                                
    						
								
                                    
                                        
                                            
                                                Number of channels:
                                            
                                            
                                        
									    2 Channel / Grab sample-Calibration Port (includes three 4-20mA outputs enabled as standard)
                                    
                                
    						
								
                                    
                                        
                                            
                                                Number of streams:
                                            
                                            
                                        
									    2
                                    
                                
    						
								
                                    
                                        
                                            
                                                Operating temperature range:
                                            
                                            
                                        
									    5 - 40 °C
                                    
                                
    						
								
                                    
                                        
                                            
                                                Oxidation method:
                                            
                                            
                                        
									    Unique Two-Stage Advanced Oxidation Process (TSAO) using Hydroxyl Radicals
                                    
                                
    						
								
                                    
                                        
                                            
                                                Parameter:
                                            
                                            
                                        
									    Direct measurement of Total Organic Carbon, Total Inorganic Carbon, Total Carbon
Chemical Oxygen Demand, Biological Oxygen Demand via correlation
Volatile Organic Carbon via calculation
                                    
                                
    						
								
                                    
                                        
                                            
                                                Particle size:
                                            
                                            
                                        
									    Up to 100 µm
                                    
                                
    						
								
                                    
                                        
                                            
                                                Permissible Chloride range:
                                            
                                            
                                        
									    Up to 30 % w/v
                                    
                                
    						
								
                                    
                                        
                                            
                                                Power requirements (Hz):
                                            
                                            
                                        
									    50 Hz
                                    
                                
    						
								
                                    
                                        
                                            
                                                Power requirements (Voltage):
                                            
                                            
                                        
									    230 V AC
                                    
                                
    						
								
                                    
                                        
                                            
                                                Power supply:
                                            
                                            
                                        
									    TIC/TOC - 230V
                                    
                                
    						
								
                                    
                                        
                                            
                                                Protection class:
                                            
                                            
                                        
									    IP44, standard fan cooled, maximum ambient temperature 45 °C 
IP54, air cooled, maximum ambient temperature 35 °C
IP54, vortex cooled, maximum ambient temperature 50 °C
                                    
                                
    						
								
                                    
                                        
                                            
                                                Range selection:
                                            
                                            
                                        
									    Automatic or Manual Range Selection
                                    
                                
    						
								
                                    
                                        
                                            
                                                Repeatability:
                                            
                                            
                                        
									    ±3 % of reading or ±0.03 mg/L, whichever is greater; 
Lower Limit of detection LOD = 0.06 mg/L
                                    
                                
    						
								
                                    
                                        
                                            
                                                Sample inlet temperature:
                                            
                                            
                                        
									    0 - 60 °C
                                    
                                
    						
								
                                    
                                        
                                            
                                                Service interval:
                                            
                                            
                                        
									    6 month service intervals
                                    
                                
    						
								
                                    
                                        
                                            
                                                User interface:
                                            
                                            
                                        
									    Microcontroller with membrane keyboard
                                    
                                
    						
								
                                    
                                        
                                            
                                                Warranty:
                                            
                                            
                                        
									    12 months
                                    
                                
    						
								
                                    
                                        
                                            
                                                Weight:
                                            
                                            
                                        
									    46 kg
                                    
                                
    						
								
                                    
                                        
                                            
                                                What's included?:
                                            
                                            
                                        
									    Includes: B3500c analyser, Tubing, Fuses, Ferrules, Drain, Acid & Base Dip Tubes, CO₂ Filter & B3500c User Manual