SC200 Controller, 2x Digital

SC200 Controller, 2x Digital
Product #: LXV404.99.05551
Unit Price Contact Hach

Maximum versatility

The SC200 controller allows the use of digital and analogue sensors, either alone or in combination, to provide compatibility with Hach's broad range of sensors, eliminating the need for dedicated, parameter-specific controllers.

Ease of use and confidence in results

Large, high-resolution, transreflective display provides optimal viewing resolution in any lighting condition. Guided calibration procedures in 19 languages minimise complexity and reduce operator error. Password-protected SD card reader offers a simple solution for data download and transfer. Visual warning system provides critical alerts.

Wide variety of communication options

Utilise two to five analogue outputs to transmit primary and secondary values for each sensor, or integrate Hach sensors and analysers into Modbus RS232/RS485, Profibus DP, and Hart networks.

Specifications

Analogue output functional mode: Linear, logarithmic, bi-linear, PID
Analogue outputs: Two (five with optional expansion module) to isolated current outputs, max 550 Ω , accuracy: ± 0.1% of FS (20mA) at 25 °C, ± 0.5% of FS over -20 °C to 60 °C range
Operational mode: measurement or calculated value
Communication: digital: Modbus RS232/RS485, Profibus
Conduit openings: 1/2“ NPT conduit
Dimensions (H x W x D): 144 mm x 144 mm x 181 mm
Display: Graphic dot matrix LCD with LED backlighting, transreflective
Display resolution: 240 x 160 pixels
Display size: 48 x 68 mm
Electrical Certifications: EMC
CE compliant for conducted and radiated emissions:
- CISPR 11 (Class A limits)
- EMC Immunity EN 61326-1 (Industrial limits)
Safety
cETLus safety mark for:
- General Locations per ANSI/UL 61010-1 & CAN/CSA C22.2. No. 61010-1
- Hazardous Location Class I, Division 2, Groups A,B,C & D (Zone 2, Group IIC) per FM 3600 / FM 3611 & CSA C22.2 No. 213 M1987 with approved options and appropriately rated Class I, Division 2 or Zone 2 sensors
cULus safety mark
- General Locations per UL 61010-1 & CAN/CSA C22.2. No. 61010-1
Enclosure waterproof rating: IP66 / NEMA 4X
Manual languages: Bulgarian, Chinese (PRC), Croatian, Czech, Danish, Dutch, English, Estonian, Finnish, French, German, Greek, Hungarian, Italian, Japanese, Korean, Lithuanian, Polish, Portuguese (Brazil), Portuguese (Portugal), Romanian, Russian, Slovak, Slovenian, Spanish, Swedish, Thai, Turkish
Material: Polycarbonate
Aluminium (powder coated)
Stainless steel
Mounting configurations: Wall, pole, and panel mounting
Operating temperature range: -20 - 60 °C at 0 - 95% RH non-condensing
Power requirements (Hz): 50/60 Hz
Power requirements (Voltage): 100 - 240 V AC, 24 V DC
Relay: Operational mode: Primary or secondary measurement, calculated value (dual channel only) or timer
Relay functions: Scheduler (timer), alarm, feeder control, event control, pulse width modulation, frequency control, and warning
Relays: Four electromechanical SPDT (Form C) contacts, 1200 W, 5 A
Security levels: 2 password-protected levels
Storage conditions: -20 - 70 °C
Warranty: 24 months
Weight: 1.7 kg