TSS Titanium2 sc Triclamp Suspended solids probe, titanium, ball valve fitting, aggressive media

TSS Titanium2 sc Triclamp Suspended solids probe, titanium, ball valve fitting, aggressive media
Product #: LXV329.99.20001
Unit Price Contact Hach

TSS sc probes have been specially developed for industrial applications

Measures both turbidity and suspended solids

8 measurement signals cover the total range and deliver measured values in conformity with the relevant standards

Excellent stability thanks to comprehensive compensation for interference factors

TSS sc has a unique compensation system to overcome the effects of air bubbles

What's included?

Turbidity & Suspended Solids sensor, user manual

Specifications

Accuracy: Turbidity up to 1000 NTU: < 5 % of measurement value or ± 0.01 NTU, whichever is greater
NTU: 5 % of measured value or ± 0.01 NTU, whichever is greater
Ambient temperature: 0 - 60 °C (briefly 80 °C)
Application: Titanium2 Corrosive Environments
Automatic wiper: No
Cable length: 10 m (optional extension cables available)
  10 m (optional extension cables available)
Calibration: Turbidity (TRB): Factory calibrated
Solids (TS): To be calibrated by customer on site
Zero point: Permanently calibrated in the factory
Calibration method: Turbidity: Formazin or Stablcal Standard (at 800 NTU). Requires a calibration kit.
Suspended Solids: Sample specific, based on gravimetric analysis with a correction factor procedure.
Controller compatibility: SC200, SC1000, SC4500. All controllers sold separately
Diameter: 40 mm
Flow: Max. 3 m/s (the presence of air bubbles affects the measurement)
Installation style: User Defined, with TriClamp
Length: Inline sensor (TriClamp): 332 mm
Maintenance interval: 1 h/month
Material: Gasket: FKM; Wiper: PA (GF), TPV
Max Temperature: 60 °C
Measurement method: Combined multiple beam alternating light method with infrared diode system and beam focusing
Turbidity (TRB): 2-channel 90º scattered light measurement in accordance with DIN EN ISO 7027, wavelength = 60 nm
Solids (TS): 90º and 120º scattered light measurement, wavelength = 60 nm
Measuring range: Turbidity (TRB): 0.001 - 9999 NTU
Solids (TSS): 0.001 - 500 g/L
Model: TSS Titanium sc
Mounting configurations: TriClamp
Operating temperature range: 0 - 60 °C
Parameter: Turbidity, Suspended Solids
Pressure range: 10 bar or 100 m
Repeatability: TSS content: < 4 %
Turbidity: < 3 %
Response time: 1 - 300 s adjustable
Special notes: Installation note:
Distance sensor–wall
> 50 cm (Turbidity)
> 10 cm (TSS)
Warranty: 24 months
Weight: approx. 1.6 kg
What's included?: Turbidity & Suspended Solids sensor, user manual