Ultraturb seawater sc turbidity sensor, 10 m cable

Ultraturb seawater sc turbidity sensor, 10 m cable
Product #: LPV415.99.32001
Unit Price Contact Hach

Large measuring range: 0.0001 - 1,000 NTU

The Hach Ultraturb plus sc Sensor measures turbidity from 0 - 1000 NTU (FNU) for a wide variety of low to medium range turbidity applications. Use it to effectively monitor conventional filtered water processes, effluent water, distribution systems, and elevated tanks where small-sized particulates or air entrapment may be an issue.

Self-Cleaning Sample Chamber Option

The Ultraturb sensor is available with an automatically self-cleaning sample chamber that guarantees stable measured values. The silicon wiper blades inside the sample chamber are held in place with a magnetic coupling wheel to further keep the sample chamber intact.

Ratio Methodology Detects Sample Chamber Fouling

The Ultraturb sensor uses ratio methodology with detection at 90° and 180° to minimize reflections in the measuring cell and on the windows. In this way, fouling of the sample chamber is detected earlier than with a single detection system.

Suitable for seawater, brackish water, raw water and other applications

The new Ultraturb seawater sc is resistant to salt concentrations up to 65 g/L.

What's included?

Hach Ultraturb seawater sc, Factory Test Certificate, 4 wipers, Accessory set LZP816, User Manual

Specifications

Accuracy: ± 0.008 FNU ±1% of reading whichever is greater
(0 - 10 FNU)
Automatic wiper: Yes
Cable length: 10 m
Calibration method: Stablcal
Dimensions (H x W x D): 240 mm x 250 mm x 110 mm
Display: Display provided through connection with Hach sc Controller
Enclosure waterproof rating: IP55
Flow rate: 0.2 to 1 L/min
Inlet: 13 mm ID Tubing or fixed connection (PVC system component pipework)
Material: Housing: ASA; Window: Quartz; Wiper Blade: Silicon; Wiper Shaft: stainless steel 1.4571
Measurement method: 90° infrared pulse scattered light technique in accordance with DIN EN ISO 7027
Measuring range: 0.0001 - 1000 FNU (TE/F, NTU, FNU) can be programmed as required (0.001-250 EBC = 2500 ppm SiO2) (Note: 1 FNU is equivalent to 1 NTU)
Model: Ultraturb seawater
Operating temperature range: 2 - 40 °C
Outlet: 13 mm ID Tubing or fixed connection (PVC system component pipework)
Pressure range: 6 bar at 20 °C
Repeatability: ± 0.003 FNU or ± 0.5% of reading (whichever is greater) from 0 - 2 FNU
Response time: 1 - 60 s (programmable)
Sample temperature: Max. 50 °C
Sensor cleaning: Wiper, automatic
Verification: Stablcal or dry standard CVM module
Warranty: 24 months
Weight: Approx. 1.5 kg
What's included?: Hach Ultraturb seawater sc, Factory Test Certificate, 4 wipers, Accessory set LZP816, User Manual