Stationary sampler with insulated stainless steel housing, separated control and sample compartment with lockable door, flexible sampling options and various bottle configurations. Sample volume accuracy, suction velocity and cooling performance certified according to MCERTs regulation. This sampler covers almost 90% of the demands in routine and is ideal for use in sewage treatment and industrial facilities and for monitoring surface waters. The sampler functions according to the pressure-vacuum principle and operates in time, volume, flow or event-based mode. The different dosage vessels make the instrument extremely flexible in standard and individual applications. The temperature-controlled weatherproof V2A housing is optional and available in V4A and plastic-coated stainless steel. The strict separation of the control and sample sections ensures that the instrument has a long life.
Optional Accessories
Recently viewed
Stationary sampler with insulated stainless steel housing, separated control and sample compartment with lockable door, flexible sampling options and various bottle configurations. Sample volume accuracy, suction velocity and cooling performance certified according to MCERTs regulation. This sampler covers almost 90% of the demands in routine and is ideal for use in sewage treatment and industrial facilities and for monitoring surface waters. The sampler functions according to the pressure-vacuum principle and operates in time, volume, flow or event-based mode. The different dosage vessels make the instrument extremely flexible in standard and individual applications. The temperature-controlled weatherproof V2A housing is optional and available in V4A and plastic-coated stainless steel. The strict separation of the control and sample sections ensures that the instrument has a long life.
BM6004625 Liter PE composite container with cap for Buehler Stationary Sampler
Overview
Stationary sampler with insulated stainless steel housing, separated control and sample compartment with lockable door, flexible sampling options and various bottle configurations. Sample volume accuracy, suction velocity and cooling performance certified according to MCERTs regulation. This sampler covers almost 90% of the demands in routine and is ideal for use in sewage treatment and industrial facilities and for monitoring surface waters. The sampler functions according to the pressure-vacuum principle and operates in time, volume, flow or event-based mode. The different dosage vessels make the instrument extremely flexible in standard and individual applications. The temperature-controlled weatherproof V2A housing is optional and available in V4A and plastic-coated stainless steel. The strict separation of the control and sample sections ensures that the instrument has a long life.
Type of distributorRound distributor for multi-bottle versions (distribution plate used for some bottle configurations)
Password ProtectionProgramm changes and internal functions can be password protected
Housing materialDouble-walled stainless steel (material 1.4301/SS304) / PS / PC (GF10) with 40 mm insulation. Housing separated in sample compartment and control compartment, each with lockable door. Upper door with PMMA window. Protective top made of Styrosun which can be opened for connection and maintenance works. Optional: 1.4571/SS316Ti; SS304 Epoxy-coated; SS316Ti Epoxy-coated
Stainless Steel
Bottle filling time
Documents & Downloads
Brochures
Brochure
Product Information Stationary & Portable Samplers
Stationary sampler with insulated stainless steel housing, separated control and sample compartment with lockable door, flexible sampling options and various bottle configurations. Sample volume accuracy, suction velocity and cooling performance certified according to MCERTs regulation. This sampler covers almost 90% of the demands in routine and is ideal for use in sewage treatment and industrial facilities and for monitoring surface waters. The sampler functions according to the pressure-vacuum principle and operates in time, volume, flow or event-based mode. The different dosage vessels make the instrument extremely flexible in standard and individual applications. The temperature-controlled weatherproof V2A housing is optional and available in V4A and plastic-coated stainless steel. The strict separation of the control and sample sections ensures that the instrument has a long life.
Type of distributorRound distributor for multi-bottle versions (distribution plate used for some bottle configurations)
Password ProtectionProgramm changes and internal functions can be password protected
Housing materialDouble-walled stainless steel (material 1.4301/SS304) / PS / PC (GF10) with 40 mm insulation. Housing separated in sample compartment and control compartment, each with lockable door. Upper door with PMMA window. Protective top made of Styrosun which can be opened for connection and maintenance works. Optional: 1.4571/SS316Ti; SS304 Epoxy-coated; SS316Ti Epoxy-coated
Stainless Steel
Bottle filling time
Documents & Downloads
Brochures
Brochure
Product Information Stationary & Portable Samplers
KeypadNumeric key pad, 4 arrow navigation keys, enter and back key
Sampler typeStationary
Languages user interfaceMulti-language, selectable
Sample containerPlastic: 1 x 25 L; 1 x 50 L; 2 x 10 L; 2 x 22 L; 4 x 10 L; 4 x 14 L; 4 x 20 L; 4 x 25 L; 12 x 2.9 L; 24 x 1,0 L; 24 x 2.9 L Glass: 12 x 2.0 L; 24 x 0.9 L; 24 x 2.0 L
Sample volume accuracyStandard Vacuum System: < 2.5 % or ± 3 mL
Sample volumeSample volume adjustable at standard dosing system 20 - 350 mL (optional Dosing Systems: Bypass, CTVV - constant time, variable volume, 500 mL dosing option)
Power SupplyApprox. 350 VA (with cooling)
Sampling PrincipleStandard Vacuum System 20 - 350 mL
Option: Vacuum System 20 - 500 mL
Option: Vacuum CTVV flow-proportional 5 - 350 mL
Option: Bypass System 20 - 250 mL
Option: glass dosing vessel instead of plastic
LoggingSample history, input signals, bottle changes, alarms in combination with time/date stamp
Suction Hose MaterialPVC
Program Start Optionsimmediately, at a certain time, at external Signal, certain weekday
Data storage3000 entries, non-volatile data memory; storage of sampling and malfunction data like sample extractions, bottle changes, messages, external signals
Warranty24 months
Sample temperature0 - 40 °C
CommunicationOptionally available Communcation interfaces for MODBUS TCP, PROFIBUS DP
Non return valveAvailable in combination with glass dosing systems
Inputs1 x analogue: 0/4-20 mA 2 x digital (flow, event), Impulse length 60 ms, switching level 7-24 V, max. working resistance 500 Ohm, max. length of signal cable 30 m
Program Stop OptionsStopp sampling after programm is passed, after a certain amount of runs or continous run mode
Suction hose inner diameter (mm)12 mm
DescriptionBuehler 401X Stationary Water Sampler, SS Enclosure
Programs12 freely programmable user programs, with function to link programs
Status messagesStandard: 1 collective malfunction message as relay output Option: expandable up to 5 relay outputs - freely programmable
Sample transport velocity>0.5 m/s at suction height up to at least 8 m (at 1013 hPa); pump performance can be adjusted electronically
Dimensions1290 (1890*) mm x 690 mm x 645 mm (H x W x D), * with opened top
Influent for Wastewater
Municipal Water
Pre-Treatment
Primary Treatment
Production Water
QA/QC Lab
Regulations
Secondary Treatment
Source Water
Surface Water
Storm Water
Water Cycle
Water Reuse
Bottle filling time adjustable 00:01 mm:hh to 999:59 mm:hh
Suction Hose Outer Diameter14 mm
Suction HeightMax. 8 m (at 1013 hPa and stagnant medium), optional higher
WeightApprox. 100 kg with composite container, higher weight when using multi bottle option and/or glass bottles
Ambient temperature-20 - 43 °C
Sample interval1 min to 99 h 59 min in steps of 1 minute 1 to 9999 pulses/sample
KeypadNumeric key pad, 4 arrow navigation keys, enter and back key
Sampler typeStationary
Languages user interfaceMulti-language, selectable
Sample containerPlastic: 1 x 25 L; 1 x 50 L; 2 x 10 L; 2 x 22 L; 4 x 10 L; 4 x 14 L; 4 x 20 L; 4 x 25 L; 12 x 2.9 L; 24 x 1,0 L; 24 x 2.9 L Glass: 12 x 2.0 L; 24 x 0.9 L; 24 x 2.0 L
Sample volume accuracyStandard Vacuum System: < 2.5 % or ± 3 mL
Sample volumeSample volume adjustable at standard dosing system 20 - 350 mL (optional Dosing Systems: Bypass, CTVV - constant time, variable volume, 500 mL dosing option)
Power SupplyApprox. 350 VA (with cooling)
Sampling PrincipleStandard Vacuum System 20 - 350 mL
Option: Vacuum System 20 - 500 mL
Option: Vacuum CTVV flow-proportional 5 - 350 mL
Option: Bypass System 20 - 250 mL
Option: glass dosing vessel instead of plastic
LoggingSample history, input signals, bottle changes, alarms in combination with time/date stamp
Suction Hose MaterialPVC
Program Start Optionsimmediately, at a certain time, at external Signal, certain weekday
Data storage3000 entries, non-volatile data memory; storage of sampling and malfunction data like sample extractions, bottle changes, messages, external signals
Warranty24 months
Sample temperature0 - 40 °C
CommunicationOptionally available Communcation interfaces for MODBUS TCP, PROFIBUS DP
Non return valveAvailable in combination with glass dosing systems
Inputs1 x analogue: 0/4-20 mA 2 x digital (flow, event), Impulse length 60 ms, switching level 7-24 V, max. working resistance 500 Ohm, max. length of signal cable 30 m
Program Stop OptionsStopp sampling after programm is passed, after a certain amount of runs or continous run mode
Suction hose inner diameter (mm)12 mm
DescriptionBuehler 401X Stationary Water Sampler, SS Enclosure
Programs12 freely programmable user programs, with function to link programs
Status messagesStandard: 1 collective malfunction message as relay output Option: expandable up to 5 relay outputs - freely programmable
Sample transport velocity>0.5 m/s at suction height up to at least 8 m (at 1013 hPa); pump performance can be adjusted electronically
Dimensions1290 (1890*) mm x 690 mm x 645 mm (H x W x D), * with opened top