EZ2727sc Total Nickel Colorimetric Analyser, 1 stream, 4x mA Output
The EZ2727sc Total Nickel Analyser, complete with the innovative SC4500 Controller, provides a precise and dependable solution for monitoring nickel levels in water. Designed for industrial and wastewater facilities, this Analyser addresses operational challenges such as inefficiencies and regulatory compliance. Its ease of integration and reliable performance help optimise processes while minimizing downtime, making it a trusted tool for critical applications.
Key Features
Flexible Customisation Adapt the EZ2727sc Total Nickel Analyser to meet your operational needs. The base model supports 1 stream and 4x mA outputs, but it can be expanded to handle up to 8 streams and 8x mA outputs, providing scalability for future requirements. Advanced connectivity options—including Modbus RTU, Modbus TCP/IP, Profibus DP, and Ethernet/IP—enable seamless system integration, streamlining data collection and process efficiency.
Reliable and Easy to Use Engineered for demanding environments, the EZ2727sc Total Nickel Analyser delivers consistently accurate nickel measurements with minimal maintenance. Its intuitive interface reduces the complexity of operation, empowering operators to focus on maintaining plant efficiency. The durable construction and low-maintenance design ensure long-term reliability, even under rigorous conditions, minimising disruptions to your workflows.
Explore Tailored Solutions Every facility has unique requirements, and the EZ2727sc Total Nickel Analyser is designed to meet those challenges. Contact us today to discover how this adaptable solution can help you improve process efficiency, achieve compliance, and maintain operational excellence. Together, we’ll configure the right solution for your needs.
The EZ2727sc Total Nickel Analyser, complete with the innovative SC4500 Controller, provides a precise and dependable solution for monitoring nickel levels in water. Designed for industrial and wastewater facilities, this Analyser addresses operational challenges such as inefficiencies and regulatory compliance. Its ease of integration and reliable performance help optimise processes while minimizing downtime, making it a trusted tool for critical applications.
Key Features
Flexible Customisation Adapt the EZ2727sc Total Nickel Analyser to meet your operational needs. The base model supports 1 stream and 4x mA outputs, but it can be expanded to handle up to 8 streams and 8x mA outputs, providing scalability for future requirements. Advanced connectivity options—including Modbus RTU, Modbus TCP/IP, Profibus DP, and Ethernet/IP—enable seamless system integration, streamlining data collection and process efficiency.
Reliable and Easy to Use Engineered for demanding environments, the EZ2727sc Total Nickel Analyser delivers consistently accurate nickel measurements with minimal maintenance. Its intuitive interface reduces the complexity of operation, empowering operators to focus on maintaining plant efficiency. The durable construction and low-maintenance design ensure long-term reliability, even under rigorous conditions, minimising disruptions to your workflows.
Explore Tailored Solutions Every facility has unique requirements, and the EZ2727sc Total Nickel Analyser is designed to meet those challenges. Contact us today to discover how this adaptable solution can help you improve process efficiency, achieve compliance, and maintain operational excellence. Together, we’ll configure the right solution for your needs.
Can't find the combination you need?
Explore the EZ sc Series Metals family to find the right product for your requirements.
APPAZ0080008Moduplex, 8 Streams, Pinch Valve, 1/8" OD
Overview
The EZ2727sc Total Nickel Analyser, complete with the innovative SC4500 Controller, provides a precise and dependable solution for monitoring nickel levels in water. Designed for industrial and wastewater facilities, this Analyser addresses operational challenges such as inefficiencies and regulatory compliance. Its ease of integration and reliable performance help optimise processes while minimizing downtime, making it a trusted tool for critical applications.
Key Features
Flexible Customisation Adapt the EZ2727sc Total Nickel Analyser to meet your operational needs. The base model supports 1 stream and 4x mA outputs, but it can be expanded to handle up to 8 streams and 8x mA outputs, providing scalability for future requirements. Advanced connectivity options—including Modbus RTU, Modbus TCP/IP, Profibus DP, and Ethernet/IP—enable seamless system integration, streamlining data collection and process efficiency.
Reliable and Easy to Use Engineered for demanding environments, the EZ2727sc Total Nickel Analyser delivers consistently accurate nickel measurements with minimal maintenance. Its intuitive interface reduces the complexity of operation, empowering operators to focus on maintaining plant efficiency. The durable construction and low-maintenance design ensure long-term reliability, even under rigorous conditions, minimising disruptions to your workflows.
Explore Tailored Solutions Every facility has unique requirements, and the EZ2727sc Total Nickel Analyser is designed to meet those challenges. Contact us today to discover how this adaptable solution can help you improve process efficiency, achieve compliance, and maintain operational excellence. Together, we’ll configure the right solution for your needs.
Trusted Equipment for Critical Operations
The EZ sc Series combines robust engineering with high-quality materials to ensure reliability 24/7. Designed for long-term performance, EZ sc Series minimises breakdowns and supports sustained operational success.
Scalable Solutions for Growing Needs
Built to evolve alongside your needs, online analysers from the EZ sc Series offer adaptable parameters and easier integration. They ensure your facility remains future proof without requiring expensive upgrades. Easily adjust parameter testing ranges and expand sample streams to accommodate innovation and growth.
Real-Time Data for Faster Decisions
The EZ sc Series offers advanced connectivity and real-time monitoring, delivering immediate access to actionable insights. Facilities utilising this technology benefit from improved reaction times, empowering more informed decision-making and quicker responses during critical situations.
Simplified Troubleshooting with Expert Support
Built-in diagnostics combined with secure remote data access make the EZ sc Series simplify issue resolution. Supported by a highly responsive team of experts, it ensures uninterrupted functionality and minimises operational downtime. By addressing and identifying issues early, EZ sc Series of online analysers helps prevent costly disruptions and repairs while maintaining system efficiency.
Clear Workflows for Predictable Outcomes
Standardised tools and guided workflows ensure consistent implementation and operation. The EZ sc Series minimises miscommunication, sets clear expectations, and reduces process inconsistencies, driving greater efficiency.
Applications
Municipal Water
Specifications
What's included?EZ2727sc Nickel Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets and Empty Containers for Reagents with Fittings
Number of sample streamsStandard: 1 Optional accessory for 2, 4, or 8 sample streams
Demineralised waterInternal dilution option: Rinse water & Dilution water
IP RatingIP44
Documents & Downloads
Brochures
Brochure
Maximum Insight with Minimal Effort : EZ sc verses EZ
The EZ2727sc Total Nickel Analyser, complete with the innovative SC4500 Controller, provides a precise and dependable solution for monitoring nickel levels in water. Designed for industrial and wastewater facilities, this Analyser addresses operational challenges such as inefficiencies and regulatory compliance. Its ease of integration and reliable performance help optimise processes while minimizing downtime, making it a trusted tool for critical applications.
Key Features
Flexible Customisation Adapt the EZ2727sc Total Nickel Analyser to meet your operational needs. The base model supports 1 stream and 4x mA outputs, but it can be expanded to handle up to 8 streams and 8x mA outputs, providing scalability for future requirements. Advanced connectivity options—including Modbus RTU, Modbus TCP/IP, Profibus DP, and Ethernet/IP—enable seamless system integration, streamlining data collection and process efficiency.
Reliable and Easy to Use Engineered for demanding environments, the EZ2727sc Total Nickel Analyser delivers consistently accurate nickel measurements with minimal maintenance. Its intuitive interface reduces the complexity of operation, empowering operators to focus on maintaining plant efficiency. The durable construction and low-maintenance design ensure long-term reliability, even under rigorous conditions, minimising disruptions to your workflows.
Explore Tailored Solutions Every facility has unique requirements, and the EZ2727sc Total Nickel Analyser is designed to meet those challenges. Contact us today to discover how this adaptable solution can help you improve process efficiency, achieve compliance, and maintain operational excellence. Together, we’ll configure the right solution for your needs.
Trusted Equipment for Critical Operations
The EZ sc Series combines robust engineering with high-quality materials to ensure reliability 24/7. Designed for long-term performance, EZ sc Series minimises breakdowns and supports sustained operational success.
Scalable Solutions for Growing Needs
Built to evolve alongside your needs, online analysers from the EZ sc Series offer adaptable parameters and easier integration. They ensure your facility remains future proof without requiring expensive upgrades. Easily adjust parameter testing ranges and expand sample streams to accommodate innovation and growth.
Real-Time Data for Faster Decisions
The EZ sc Series offers advanced connectivity and real-time monitoring, delivering immediate access to actionable insights. Facilities utilising this technology benefit from improved reaction times, empowering more informed decision-making and quicker responses during critical situations.
Simplified Troubleshooting with Expert Support
Built-in diagnostics combined with secure remote data access make the EZ sc Series simplify issue resolution. Supported by a highly responsive team of experts, it ensures uninterrupted functionality and minimises operational downtime. By addressing and identifying issues early, EZ sc Series of online analysers helps prevent costly disruptions and repairs while maintaining system efficiency.
Clear Workflows for Predictable Outcomes
Standardised tools and guided workflows ensure consistent implementation and operation. The EZ sc Series minimises miscommunication, sets clear expectations, and reduces process inconsistencies, driving greater efficiency.
Applications
Municipal Water
Specifications
What's included?EZ2727sc Nickel Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets and Empty Containers for Reagents with Fittings
Number of sample streamsStandard: 1 Optional accessory for 2, 4, or 8 sample streams
Demineralised waterInternal dilution option: Rinse water & Dilution water
IP RatingIP44
Documents & Downloads
Brochures
Brochure
Maximum Insight with Minimal Effort : EZ sc verses EZ
Relays5 contacts, not user configurable: Malfuntion, maintenance, analysis ready, sample ready, sample ready (EZ9150)
ParameterNickel, total
Instrument airDry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air. Used to flush the instrument in corrosive environement. Min. 0.2 bar - Max. 0.5 bar
ModelEZ2727sc
CertificationsCE, ETL certified to UL and CSA safety standards, UKCA
InterferencesMetal ions like Aluminium Al(III), Bismuth Bi(II), Cadmium Cd(II), Chromium Cr(III), Cobalt Co(II), Copper Cu(II), Iron Fe(II), Iron Fe(III), Lead Pb(II), Manganese Mn(II), Magnesium Mg(II), Mercury Hg(II), Palladium Pd(II), Platinum Pt(II), Silver Ag(I), Tin Sn(II), Zinc Zn(II). Large amounts of colour and turbidity interferes. Fats, oil, proteins, surfactants and tar.
CalibrationAutomatic; 2-point; Frequency freely programmable: 6 hours, 12 hours, daily, weekly. Note: manufacturer recommends that a calibration is done when the reagents are replaced
Dimensions (H x W x D)688 mm x 460 mm x 340 mm
Measurement method
Colorimetric
Colorimetric measurement using DMG colour solution
Power230 VAC, 50/60 Hz Max. power consumption: 240 VA
DrainAtmospheric pressure, vented, min. Ø 32 mm
Alarm1 x malfunctioning, 4 x user-configurable, max. 24 VDC/0.5 A, potential free contacts
Cooling waterFlow rate approx. 5 L/h; temperature max. 30 °C; pressure max. 0.5 bar
Analogue outputsActive 4 - 20 mA max. 500 Ohm load, standard 4, max. 8 (option)
Reagent RequirementsKeep Buffer between 10 - 25 °C, all other between 10 - 30 °C
OutputOptional: Claros Ethernet connection and Modbus TCP/IP Ethernet connector; LAN version; 10/100 Mbps or Profinet or Ethernet IP
WeightMax. 35 kg
Ambient temperature10 - 30 °C ± 4 °C deviation at 5 - 95% relative humidity (non-condensing)
Digital outputsProfibus DP or Modbus RTU
Cycle TimeNo Dilution Default: 30 min. Continous: 28 min.
Internal Dilution Default: 31 min. Continous 31 min.
Sample pressureBy external overflow vessel (open to atmospheric pressure)
Earth connectionDry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm²
Relays5 contacts, not user configurable: Malfuntion, maintenance, analysis ready, sample ready, sample ready (EZ9150)
ParameterNickel, total
Instrument airDry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air. Used to flush the instrument in corrosive environement. Min. 0.2 bar - Max. 0.5 bar
ModelEZ2727sc
CertificationsCE, ETL certified to UL and CSA safety standards, UKCA
InterferencesMetal ions like Aluminium Al(III), Bismuth Bi(II), Cadmium Cd(II), Chromium Cr(III), Cobalt Co(II), Copper Cu(II), Iron Fe(II), Iron Fe(III), Lead Pb(II), Manganese Mn(II), Magnesium Mg(II), Mercury Hg(II), Palladium Pd(II), Platinum Pt(II), Silver Ag(I), Tin Sn(II), Zinc Zn(II). Large amounts of colour and turbidity interferes. Fats, oil, proteins, surfactants and tar.
CalibrationAutomatic; 2-point; Frequency freely programmable: 6 hours, 12 hours, daily, weekly. Note: manufacturer recommends that a calibration is done when the reagents are replaced