Orbisphere GA2800 ATEX Oxygen Sensor (EC), Hastelloy, 100 bar, FKM/FPM O-rings
GA280E-HVSProduct Number: GA280E-HVS
Measuring range
Range at 25 °C
2935A-A: 10 ppb - 400 ppm or 20 Pa - 1,000 kPa
2952A-A: 1 ppb - 80 ppm or 5 Pa - 200 kPa
2956A-A: 0.1 ppb - 20 ppm or 0.25 Pa - 50 kPa
29552A-A: 2 ppb - 80 ppm or 5 Pa - 200 kPa
2935A-A: 10 ppb - 400 ppm or 20 Pa - 1,000 kPa
2952A-A: 1 ppb - 80 ppm or 5 Pa - 200 kPa
2956A-A: 0.1 ppb - 20 ppm or 0.25 Pa - 50 kPa
29552A-A: 2 ppb - 80 ppm or 5 Pa - 200 kPa
Accuracy
Accuracy = Trueness (ISO 57251)
2935A-A: The greater of ±1% of reading or ± 10 ppb, or ± 20 Pa
2952A-A: The greater of ±1% of reading or ± 2 ppb, or ± 5 Pa
2956A-A: The greater of ±1% of reading or ± 0.1 ppb¹, or ± 1 ppb², or ± 0.25 Pa
29552A-A: The greater of ±1% of reading or ± 2 ppb, or ± 5 Pa
¹ Accuracy is ± 0.1 ppb for 410, 510, 362x, 360x and 3655 instruments
² Accuracy is ± 1 ppb for 366x and 3650 instruments
2935A-A: The greater of ±1% of reading or ± 10 ppb, or ± 20 Pa
2952A-A: The greater of ±1% of reading or ± 2 ppb, or ± 5 Pa
2956A-A: The greater of ±1% of reading or ± 0.1 ppb¹, or ± 1 ppb², or ± 0.25 Pa
29552A-A: The greater of ±1% of reading or ± 2 ppb, or ± 5 Pa
¹ Accuracy is ± 0.1 ppb for 410, 510, 362x, 360x and 3655 instruments
² Accuracy is ± 1 ppb for 366x and 3650 instruments
Wetted Materials
Hastelloy
No O-rings are in contact with the sample
No O-rings are in contact with the sample
Certifications
CE, Ex II 1 G, Ex ia IIC T6
Measuring range
Range at 25 °C
2935A-A: 10 ppb - 400 ppm or 20 Pa - 1,000 kPa
2952A-A: 1 ppb - 80 ppm or 5 Pa - 200 kPa
2956A-A: 0.1 ppb - 20 ppm or 0.25 Pa - 50 kPa
29552A-A: 2 ppb - 80 ppm or 5 Pa - 200 kPa
2935A-A: 10 ppb - 400 ppm or 20 Pa - 1,000 kPa
2952A-A: 1 ppb - 80 ppm or 5 Pa - 200 kPa
2956A-A: 0.1 ppb - 20 ppm or 0.25 Pa - 50 kPa
29552A-A: 2 ppb - 80 ppm or 5 Pa - 200 kPa
Accuracy
Accuracy = Trueness (ISO 57251)
2935A-A: The greater of ±1% of reading or ± 10 ppb, or ± 20 Pa
2952A-A: The greater of ±1% of reading or ± 2 ppb, or ± 5 Pa
2956A-A: The greater of ±1% of reading or ± 0.1 ppb¹, or ± 1 ppb², or ± 0.25 Pa
29552A-A: The greater of ±1% of reading or ± 2 ppb, or ± 5 Pa
¹ Accuracy is ± 0.1 ppb for 410, 510, 362x, 360x and 3655 instruments
² Accuracy is ± 1 ppb for 366x and 3650 instruments
2935A-A: The greater of ±1% of reading or ± 10 ppb, or ± 20 Pa
2952A-A: The greater of ±1% of reading or ± 2 ppb, or ± 5 Pa
2956A-A: The greater of ±1% of reading or ± 0.1 ppb¹, or ± 1 ppb², or ± 0.25 Pa
29552A-A: The greater of ±1% of reading or ± 2 ppb, or ± 5 Pa
¹ Accuracy is ± 0.1 ppb for 410, 510, 362x, 360x and 3655 instruments
² Accuracy is ± 1 ppb for 366x and 3650 instruments
Wetted Materials
Hastelloy
No O-rings are in contact with the sample
No O-rings are in contact with the sample
Certifications
CE, Ex II 1 G, Ex ia IIC T6